Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này:
https://dspace.ctu.edu.vn/jspui/handle/123456789/109873
Nhan đề: | Phenol biological treatment in wastewater by laboratory scale = Xử lý phenol trong nước thải bằng công nghệ sinh học ở quy môn phòng thí nghiệm |
Tác giả: | Le, Ngoc Thuan Vu, Thi Mai |
Từ khoá: | Activated sludge reactor Industrial wastewater Phenol removal |
Năm xuất bản: | 2024 |
Tùng thư/Số báo cáo: | Tạp chí Xây dựng;Số 679 .- Tr.128-130 |
Tóm tắt: | Experiments used an aerobic activated sludge reactor to investigate the removal of phenol and formaldehyde from wastewater on a laboratory scale. An activated sludge reactor module with a volume of 70 L, starts up with 10 hours of hydraulic retention time pH value in the range of 6.8-7, the DO in the anoxic compartment is always less than 0.5 mg/L, in the aerobic compartment between the values of 3.0 and 4.5 mg/L The results showed that the activated sludge after the start up process was stable with MLSS 2800 mg/L to 3170 (mg/L), sludge volume index (SVl₃₀) was 156.7 ml/g, and activated sludge showed good sedimentation ability. Phenol in influent less than 200 mg/L, the removal performance of activated sludge reactor is very good, almost all phenol is removed from the wastewater. When treating wastewater with a mixture of phenol and formaldehyde, there is a reduction in treatment efficiency when increasing the pollutant concentration, at a concentration of 300 mg/L of formaldehyde and phenol, only 82.36%, and 72.63% respectively is eliminated. Activated sludge reactor can be used to treat industrial phenol and formaldehyde containing wastewater. |
Định danh: | https://dspace.ctu.edu.vn/jspui/handle/123456789/109873 |
ISSN: | 2734-9888 |
Bộ sưu tập: | Xây dựng |
Các tập tin trong tài liệu này:
Tập tin | Mô tả | Kích thước | Định dạng | |
---|---|---|---|---|
_file_ Giới hạn truy cập | 360.48 kB | Adobe PDF | ||
Your IP: 3.128.205.187 |
Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.