Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này:
https://dspace.ctu.edu.vn/jspui/handle/123456789/12613
Nhan đề: | Determine dose-saturation level from thermoluminescence curves by the GOK and OTOR models |
Tác giả: | Nguyễn, Duy Sang Nguyễn, Văn Hùng Nguyễn, Quốc Hiến Trần, Văn Hùng |
Từ khoá: | Saturation Thermoluminescence Kinetic parameters GOK OTOR |
Năm xuất bản: | 2018 |
Tùng thư/Số báo cáo: | Journal of Taibah University for Science;12 .- p. 846-851 |
Tóm tắt: | This study shows that the pre-exponential frequency in the general-orders of kinetics (GOK) model depends on the ratio between the initial number of trapped electrons (n0) and the total concentration of trapping states (N) as well as the frequency factor. The frequency factor can be calculated by the one trap-one recombination (OTOR) model and does not depend on the ratio of n0/N. That means the ratio of n0/N can be deduced based on a comparison of the GOK and OTOR models. When the ratio of n0/N is approximately 1, the sample is in the dose-saturation level. Therefore, at the first time, this study has been determined the dose-saturation level of the sample from the thermoluminescence (TL) curve fitting. |
Định danh: | http://dspace.ctu.edu.vn/jspui/handle/123456789/12613 |
ISSN: | 1658-3655 |
Bộ sưu tập: | Tạp chí quốc tế |
Các tập tin trong tài liệu này:
Tập tin | Mô tả | Kích thước | Định dạng | |
---|---|---|---|---|
_file_ | 1.75 MB | Adobe PDF | Xem | |