Please use this identifier to cite or link to this item: https://dspace.ctu.edu.vn/jspui/handle/123456789/40786
Title: Study of ozone disinfection in the hospital environment
Authors: Le, Hoang Tu
Le, Hoang Oanh
Nguyen, Vu Trung
Le, Cao Cuong
Doan, Thi Yen Oanh
Tran, Vinh Dieu
Nguyen, Hoang Nghi
Keywords: Hospital-acquired infection
Ozone disinfection
Operative theatre
Agar dish
CFU
Issue Date: 2020
Series/Report no.: Vietnam Journal of Chemistry;Vol. 58, No. 04 .- P.565-568
Abstract: Hundreds of millions of patients are affected by health care-associated infections worldwide each year. In the hospitals, contaminated surfaces and air may play an important role in the transmission of respiratory pathogens. Recently, ozone disinfection is employed and shows the effectiveness as an alternative sanitizing technology to conventional disinfectants in reducing the microbial contamination in air as well as in the surfaces of the functional rooms of the hospitals. In this paper, the disinfection capacity of ozone gas is investigated by means of analysing the CFU reduction during ozonation of an operative theatre in Ha Dong polyclinic hospital (Hanoi, Vietnam). The full removal of the microorganisms and fungi in the operative theatre during ozonation was achieved by using ozone of 5 ppm concentration and exposure time of 40-60 min.
URI: https://dspace.ctu.edu.vn/jspui/handle/123456789/40786
ISSN: 2525-2321
Appears in Collections:Vietnam Journal of Chemistry

Files in This Item:
File Description SizeFormat 
_file_
  Restricted Access
1.27 MBAdobe PDF
Your IP: 18.116.13.192


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.