Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này: https://dspace.ctu.edu.vn/jspui/handle/123456789/40786
Nhan đề: Study of ozone disinfection in the hospital environment
Tác giả: Le, Hoang Tu
Le, Hoang Oanh
Nguyen, Vu Trung
Le, Cao Cuong
Doan, Thi Yen Oanh
Tran, Vinh Dieu
Nguyen, Hoang Nghi
Từ khoá: Hospital-acquired infection
Ozone disinfection
Operative theatre
Agar dish
CFU
Năm xuất bản: 2020
Tùng thư/Số báo cáo: Vietnam Journal of Chemistry;Vol. 58, No. 04 .- P.565-568
Tóm tắt: Hundreds of millions of patients are affected by health care-associated infections worldwide each year. In the hospitals, contaminated surfaces and air may play an important role in the transmission of respiratory pathogens. Recently, ozone disinfection is employed and shows the effectiveness as an alternative sanitizing technology to conventional disinfectants in reducing the microbial contamination in air as well as in the surfaces of the functional rooms of the hospitals. In this paper, the disinfection capacity of ozone gas is investigated by means of analysing the CFU reduction during ozonation of an operative theatre in Ha Dong polyclinic hospital (Hanoi, Vietnam). The full removal of the microorganisms and fungi in the operative theatre during ozonation was achieved by using ozone of 5 ppm concentration and exposure time of 40-60 min.
Định danh: https://dspace.ctu.edu.vn/jspui/handle/123456789/40786
ISSN: 2525-2321
Bộ sưu tập: Vietnam Journal of Chemistry

Các tập tin trong tài liệu này:
Tập tin Mô tả Kích thước Định dạng  
_file_
  Giới hạn truy cập
1.27 MBAdobe PDF
Your IP: 18.217.237.68


Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.