Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này: https://dspace.ctu.edu.vn/jspui/handle/123456789/4883
Nhan đề: Fault Tolerant Control of DC-Link Voltage Sensor for Three-Phase AC/DC/AC PWM Converters
Tác giả: Kim, Soo-Cheol
Nguyễn, Thanh Hải
Lee, Dong-Choon
Kim, Jang-Mok
Lee, Kyo-Beum
Từ khoá: DC-link voltage
Estimation
Fault tolerant control
Luenberger observer
PWM converter
Năm xuất bản: 2014
Tùng thư/Số báo cáo: Journal of Power Electronics;14 .- p.695-703
Tóm tắt: In this paper, a fault detection scheme for DC-link voltage sensor and its fault tolerant control strategy for three-phase AC/DC/AC PWM converters are proposed, where the Luenberger observer is applied to estimate the DC-link voltage. The Luenberger observer is based on a converter model, which is derived from the voltage equations of a grid-side converter and the power balance on a DC link. A fault of the voltage sensor is detected by comparing the measured value of the DC-link voltage with the estimated one. When a sensor fault is detected, a fault tolerant control strategy is performed, where the estimated DC-link voltage is used for the feedback control. The estimation error from the observer is about 1.5 V, which is sufficiently accurate for feedback control. In addition, it is shown that the observer performance is robust to parameter variations of the converter. The validity of the proposed method has been verified by simulation and experimental results.
Định danh: http://dspace.ctu.edu.vn/jspui/handle/123456789/4883
ISSN: 2093-4718
Bộ sưu tập: Tạp chí quốc tế

Các tập tin trong tài liệu này:
Tập tin Mô tả Kích thước Định dạng  
_file_808.3 kBAdobe PDFXem
Your IP: 13.58.191.60


Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.