Please use this identifier to cite or link to this item: https://dspace.ctu.edu.vn/jspui/handle/123456789/54719
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDo, Thi My Dung-
dc.contributor.authorLam, Thanh Quang Khai-
dc.date.accessioned2021-06-09T09:28:21Z-
dc.date.available2021-06-09T09:28:21Z-
dc.date.issued2021-
dc.identifier.issn2734-9888-
dc.identifier.urihttps://dspace.ctu.edu.vn/jspui/handle/123456789/54719-
dc.description.abstractThis paper presents the results of an experimental study involved testing of double-layer reinforced concrete beams in two cases: Steel fiber concrete layer is located below, and is located above of the normal concrete layer. The size of the beams is 15x30x220cm. in which the steel fiber concrete layer is 10cm thick, all the beam samples were tested under two-point loads. ANSYS has simulated experimental beams as load-vertical displacement relationship, load- compression strain relationship, load-tensile strain relationship at the middle of the span of the beams. Experimental results and numerical installation of ANSYS of double-layer steel fiber concrete beams were compared with three-layer steel fiber reinforced concrete beams of the same size. In three-layer steel fiber reinforced concrete beams, the 10cm thick steel fiber concrete layer is located below, and is located above, a middle layer is the normal concrete layer. Concrete of beams is B30 for all layers, all types of beams with steel fiber content in concrete is 2% by volume, with nonlinear material analysis in ANSYS numerical simulation. The data are compared with each other results show that the two-layer Steel fiber reinforced concrete beams are damaged the slowest, the three-layer fiber concrete beams are damaged very early in other beams. Experimental results also show that the vertical displacement, tensile strain and compressive strain values are 30-40% larger than the simulated 2-layer and 3-layer beams.vi_VN
dc.language.isovivi_VN
dc.relation.ispartofseriesTạp chí Xây dựng Việt Nam;Số 635 .- Tr.58-63-
dc.subjectNonlinear analysisvi_VN
dc.subjectConcrete beamsvi_VN
dc.subjectMulti-layer steelvi_VN
dc.titleNonlinear analysis of multi-layer steel fiber reinforced concrete beamsvi_VN
dc.typeArticlevi_VN
Appears in Collections:Xây dựng

Files in This Item:
File Description SizeFormat 
_file_
  Restricted Access
1.84 MBAdobe PDF
Your IP: 18.119.28.173


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.